All products

D-Dimer Rapid Quantitative Test

Specimen Types: WB/Plasma Specimen Capacity: WB:80μL; Plasma:50μL Reaction Time: 3 min Detection Range: 0.1-10mg/L Clinical Significance: <0.5mg/L: No risk of DVT&PE

NT-proBNP Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:80μL; Plasma/Serum:50μL Reaction Time: 15 min Detection Range: 15-35000pg/mL Clinical Significance: <75Years old,300-900pg/mL & ≥75Years old,450-1800pg/mL Low risk of HF <75Years old,≥900pg/mL & ≥75Years old, ≥1800pg/mL High risk of HF

BNP B Type Natriuretic Peptide Test

Specimen Types: WB/Plasma Specimen Capacity: WB:80μL; Plasma:50μL Reaction Time: 10 min Sample Capacity: 80μL Detection Range: 10-5000pg/mL

HCY Homocysteine Rapid Quantitative Test

Specimen Types: Plasma Specimen Capacity: 10μL Reaction Time: 15 min Sample Capacity: 80μL Detection Range: 2-50μmol/L

ST2 Cardiovascular Rapid Quantitative Test

Specimen Types: Serum Specimen Capacity: 50μL Reaction Time: 15 min Sample Capacity: 80μL Detection Range:2-200.0ng/mL

Lp-PLA2 Atherosclerosis Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:15μL; Plasma/Serum:10μL Reaction Time: 10 min Sample Capacity: 80μL Detection Range: 5-800.0ng/mL

2 in 1(CRP/SAA) Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:5μL; Serum/Plasma:3μL Reaction Time: 3 min Sample Capacity: 80μL Detection Range: SAA: 1.0-200.0mg/L; CRP: 5.0-200.0mg/L

CRP C-reactive protein Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:5μL; Serum/Plasma:3μL Reaction Time: 3 min Sample Capacity: 80μL Detection Range: 0.5-200mg/L

SAA Serum amyloid A Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:5μL; Serum/Plasma:3μL Reaction Time: 3 min Sample Capacity: 80μL Detection Range:1-200mg/L

PCT Procalctonin Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:80μL; Serum/Plasma:50μL Reaction Time: 15 min Sample Capacity: 80μL Detection Range0.1-100ng/mL

Total IgE Rapid Quantitative Test

Specimen Types: WB/Plasma/Serum Specimen Capacity: WB:30μL; Serum/Plasma:20μL Reaction Time: 12 min Sample Capacity: 80μL Detection Range:1-1000IU/mL

IL-6 Interleukin Rapid Quantitative Test

Specimen Types: Plasma/Serum Specimen Capacity: 50μL Reaction Time: 15 min Sample Capacity: 80μL Detection Range: 5-1000pg/mL

HbA1c Blood Glucose Rapid Quantitative Test

Specimen Types: WB Specimen Capacity: 5μL Reaction Time: 5 min Sample Capacity: 80μL Detection Range: 4-15%

MAU Microalbumin Rapid Quantitative Test

Specimen Types: Urine Specimen Capacity: 10μL Reaction Time: 10min Sample Capacity: 80μL Detection Range: 2-300mg/L

Cys-C Renal Function Rapid Quantitative Test

Specimen Types: WB/Plasma Specimen Capacity: WB:15μL; Plasma:10μL Reaction Time: 5 min Sample Capacity: 80μL Detection Range: 0.2-8mg/L

BIOT-YG-I FIA Immunoassay Analyzer (Fluorescence Immunoassay Analyzer)

✔ Checking machine itself allowed ✔ Remote software upgrade allowed ✔ Automatic identification of test item ✔ Test results come out in 3 to 20 min ✔ Rapid test model and standard test model allowed

NGAL Renal Injury Rapid Quantitative Test

Specimen Types: Urine Specimen Capacity: 10μL Reaction Time: 10min Sample Capacity: 80μL Detection Range: 10-5000ng/mL

FLI-600 FIA Fluorescent Immunoassay Analyzer

Advantages ✔ Multi Channels: 6 channels to test simultaneously✔ Robust: One-Key switch✔ Easy to Operate: 10.1 inch touch screen with wins10 operation system✔ Intelligent: Trend chart of patient test records✔ Zero Pollution: With discard holder provided

BIOT-YG-II FIA Multi Parameter Immunoassay Analyzer

Convenience& Rapid - Easy Operation - Test results in 3~20 minutes - Test speed is up to 200 T/h - Automatic collection of used the cartridge

FLI-1200 FIA Automated Fluorescent Immunoassay Analyzer

Multi Function - 12 samples tested in one time - Incubated in the machine - Directly connect or WIFI connect with a printer

Showing 2 to 3 of 3 (2 Pages)